Determination of the law of control pressure change over the valves of a pneumatically operated micropump
Authors: Petrov V.A., Gerasimenko T.N., Kindeeva O.V., Khaustov A.I.
Published in issue: #7(67)/2017
DOI: 10.18698/2308-6033-2017-7-1662
Category: Power, Metallurgic and Chemical Engineering | Chapter: Hydraulic machines and hydropneumatic agregates
The purpose of this research was to carry out mathematical simulation of a membrane pneumatically operated micropump. Such pumps are widely used to circulate the medium in microfluidic devices applied in various fields of science and technology. A micropump consists of three thin-walled membranes: two valves and one membrane of the working chamber. The pump is operated according to a special algorithm by alternating supply of compressed and vacuum air to the membranes of the valves and the working chamber from the control unit. Definition of a new pressure value over the valves and the working chamber is not instantaneous, so a limitation is imposed on the switching frequency of the valves and the working chamber. The purpose of the work is to determine the law of pressure change over the membranes and to find a limitation on the frequency of their switching. Dependences describing the increase and decrease in the pressure value above the working chamber are obtained and tested experimentally on a specially designed stand. The results of mathematical modeling are in good agreement with the experimental data.
References
[1] Yang H., Tsai T.H., Hu C.C. Portable valve-less peristaltic micropump design and fabrication. DTIP of MEMS andMOEMS, 2008, 9-11 April, pp. 273-278.
[2] Yang C.-C., Miao J.-M., Lih F.-L., Liu T.L., Ho M.H. The performance analysis of valveless micropump with contoured nozzle/diffuser. International Journal of Mechanical, Aerospace, Industrial, Mechatronic and Manufacturing Engineering, 2011, vol. 5, no. 2, pp. 199-204.
[3] Kar S., McWhorter S., Ford S.M., Soper S.A. Piezoelectric mechanical pump with nanoliter per minute pulse-free flow delivery for pressure pumping in micro-channels. Analyst, 1998, vol. 123, pp. 1435-1441.
[4] Robinson S. Driving piezoelectric actuators. Power Electronics Technology, 2006, April, pp. 40-44.
[5] Blanchard D., Ligrani P., Gale B. Single-disk and double-disk viscous micropumps. Sensors and Actuators, A Physical, 2005, vol. 122, no. 1, pp. 149-158.
[6] Woias P. Micropumps: summarizing the first two decades. Proceedings of SPIE - The International Society for Optical Engineering, 2001, vol. 4560, pp. 39-52.
[7] Inman W., Domansky K., Serdy J., Owens B., Trumper D., Griffith L. Design, modeling and fabrication of a constant flow pneumatic micropump. Journal of Micromechanics and Microengineering, 2007, vol. 17, no. 5, pp. 891-899.
[8] Yamada T., Ando S., Naruse Y. Pneumatically driven micro-pump. US 5499909 A, 1996.
[9] Nedelcu O.T., Morelle J.-L., Tibeica C., Voccia S., Codreanu I., Dahms S. Modelling and simulation of a pneumatically actuated micropump. Proceedings of International Semiconductor Conference, CAS, 2007, vol. 1, pp. 77-80.
[10] Huang C.-W., Huang S.-B., Lee G.-B. Pneumatic micropumps with serially connected actuation chambers. Journal of Micromechanics and Microengineering, 2006, vol. 16, no. 11, pp. 2265-2272.
[11] Busek M., Notzel M., Polk C., Sonntag F. Characterization and simulation of peristaltic micropumps. Journal of Sensors and Sensor Systems, 2013, vol. 2, no. 2, pp. 165-169.
[12] Malozemov V.V., Rozhnov V.F., Pravetskiy V.N. Sistemy zhizneobespecheniya ekipazhey letatelnykh apparatov [Life support systems for aircraft crews]. Moscow, Mashinostroenie Publ., 1986, 584 p.